Zenit ZEN-DGE100/2/G50HTSIC Submersible Vortex Pump
Suitable with slightly soiled biological wastewaters and sewage. Suitable for domestic and residential use. (3 phase pumps require contractor and overload)
Technical Data:
- Max Flow: 480LT/min
- Max Head: 12.5m
- Horse Power: 1.2HP
- Number of poles: 2
- Rated power output (P2): 0.88kW
- Input power (P1): 0.4kW
- Nominal absorbed current (In): 6.00A
- Rated power factor(cos phi): 0.96
- Nominal power frequency (f): 50 Hz
- Rated nominal voltage(Vn): 415 V
- N° phases: 3 (3 phase pumps require contractor and overload)
- IPMotor: 68
- ATEX thermal class: not applicable
- Insulation class: F
Constructive Characteristics:
- Outlet: G2″ DN50 PN10
- Outlet orientation: H (horizontal)
- Type of starting: D
- Weight: 0 kg
- Standard cable type: H07RN-F 3G1
- EX cable type: N.A.
- Standard paint type: Bicomponent epoxy paint
- Maximum acoustic pressure: 70 dB
- Set of standard mechanical seals: One Silicon carbide mechanical seal (SiC)
Use Limits:
- Maximum operating temperature: 40 °C
- Maximum immersion depth: 20 m
- PH of treated fluid: 6 to 14 pH
- Max starts per hour: 30
Materials:
- Case: Grey Cast Iron – EN-GJL 250 (02)
- Shaft: Stainless Steel – AISI 420 (23)
- Cooling jacket: Not applicable (00)
- Standard gasket: Rubber – NBR (77)
- EX gasket Not applicable (00)
- Nuts and bolts: Stainless Steel – Class A2-70 (42)
- Hydraulic: Grey Cast Iron – EN-GJL 250 (02)
- Impeller: Grey Cast Iron – EN-GJL 250 (02)
- Cutting disk: Not applicable (00)
- Cutter Not applicable (00)
- Grid: Stainless Steel – AISI 304 (20)
Test Limits:
- Density of treated fluid 1 Kg/dm³
- Viscosity of treated fluid 1 mm²/s
2 Year Zenit Warranty